Availability: | |
---|---|
Quantity: | |
Sandwich Structure 32U Outdoor Telecom Cabinet Weatherproof Rack Enclosure
Sandwich Structutre Galvanized Steel 32U Outdoor Telecom Cabinet Waterproof Equipment Cabinet Outdoor 19 Rack Enclosure
1. Outdoor cabinet application
· Telecommunications
· Data communications
· IT & Network system
· ETC-Electronic Toll Collection
· Data management
· Defence / Government
· Power supply and management
· Fiber & cable management
· Telecommunication
· Power, Oil & Gas
· Engineer and constructions
· customs
· Energy such as solar energy, wind energy, energy saving
2. Outdoor cabinet brief introduction
Model DX7575175-EQ4 is an outdoor equipment cabinet with 32U 19 inch avaliable space. Air conditioner and fan are adopted for cooling. It is equipped with power distribution box and LED lamp &lamp switch.
3. Technical parameter of outdoor Telecom cabinet
No. | Description | Specification |
I | Specification of cabinet | |
1 | Model | DX7575175-EQ4 |
2 | Cabinet Dimension | W*D*H 750*750*1750mm |
3 | Height of 19-inch rack | 32U |
4 | Door | Front door access, door open angle can be reach 110°, integrated AC220V 50Hz air conditioner 1500W |
5 | Lock | Outdoor special anti-theft three point locking(bottom, top and middle) |
6 | Material | Sandwich structure panel, double wall, galvanized steel, with heat insulation |
7 | Cabinet Installation method | Ground installation |
8 | Cable Entry | Located on the bottom |
9 | Lifting | 4 ears on the cabinet base |
10 | Earthing | Grounding copper bar |
11 | Working Temperature | -40°C~+75°C |
12 | Protection Level | IP55 |
13 | Relative Humidity | 5% ~ 100% |
14 | Atmospheric Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
15 | Solar Radiation Intensity | 1120 ×(1±5%)W/m2 |
II | Specification of air conditioner | |
1 | Rated cooling capacity | 1500W |
2 | Rated heating capacity | 300/500W (optional) |
3 | Rated input current | 2.6A |
4 | Rated input power | 580W |
5 | Rated input voltage | 220±15%VAC~50Hz |
7 | Noise | 65dB |
8 | IP Grade | IP55 |
9 | Weight | 24kg |
10 | Working environmental temperature | -40°C ~ 55°C |
11 | Storage working temperature | -40°C ~ 70°C |
12 | Working humidity | ≤95% |
III | Other accessories | |
1 | AC distribution box | AC input: 63A MCB *1 AC output 10A socket *5 Including SPD, 40KA Height: 3U |
2 | LED light | DC48V |
3 | LED light switch | Control light on or off |
4 | Ventilation fan | Two AC220V fans |
4. Cabinet Feature
(1) Embedded structure design make the door strong and protect from illigal open.
(2) Sandwich structure panel, double layer galvanized steel plate with heat insulation.
(3) Air conditioner cooling can provid good conditions for internal cooling equipment
(4) 19 inch standard rack.
(5) Protection grade IP55, effectively prevent rainwater leakage.
(6) The door lock adopts the special mechanical lock for outdoor cabinet, and the three-point locking structure provides reliable safety protection for the cabinet.
5. Cabinet Advantage
· Double wall with heat insulation can protect inside equipment against sudden heat shock
· Multi-stage cleaning and pre-treatment prior to the application of a 120micron powder coating
· The cabinet structure have earthquake resistance function
· Outdoor cabinet is compact and durable, space layout is reasonable, greatly reducing the construction cost
· Waterproof, fire proof, anti-corrosion, anti sand and anti ultraviolet, ensure cabinet can work longer in a harsh outdoor environment
· Inside screws, improve the safety
6. Cabinet Picture Display
7. Cabinet Power Distribution unit diagram
8. Other outdoor telecom cabinet
Tag:
telecom equipment cabinet,outdoor telecom enclosure,outdoor communication cabinets
Sandwich Structure 32U Outdoor Telecom Cabinet Weatherproof Rack Enclosure
Sandwich Structutre Galvanized Steel 32U Outdoor Telecom Cabinet Waterproof Equipment Cabinet Outdoor 19 Rack Enclosure
1. Outdoor cabinet application
· Telecommunications
· Data communications
· IT & Network system
· ETC-Electronic Toll Collection
· Data management
· Defence / Government
· Power supply and management
· Fiber & cable management
· Telecommunication
· Power, Oil & Gas
· Engineer and constructions
· customs
· Energy such as solar energy, wind energy, energy saving
2. Outdoor cabinet brief introduction
Model DX7575175-EQ4 is an outdoor equipment cabinet with 32U 19 inch avaliable space. Air conditioner and fan are adopted for cooling. It is equipped with power distribution box and LED lamp &lamp switch.
3. Technical parameter of outdoor Telecom cabinet
No. | Description | Specification |
I | Specification of cabinet | |
1 | Model | DX7575175-EQ4 |
2 | Cabinet Dimension | W*D*H 750*750*1750mm |
3 | Height of 19-inch rack | 32U |
4 | Door | Front door access, door open angle can be reach 110°, integrated AC220V 50Hz air conditioner 1500W |
5 | Lock | Outdoor special anti-theft three point locking(bottom, top and middle) |
6 | Material | Sandwich structure panel, double wall, galvanized steel, with heat insulation |
7 | Cabinet Installation method | Ground installation |
8 | Cable Entry | Located on the bottom |
9 | Lifting | 4 ears on the cabinet base |
10 | Earthing | Grounding copper bar |
11 | Working Temperature | -40°C~+75°C |
12 | Protection Level | IP55 |
13 | Relative Humidity | 5% ~ 100% |
14 | Atmospheric Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
15 | Solar Radiation Intensity | 1120 ×(1±5%)W/m2 |
II | Specification of air conditioner | |
1 | Rated cooling capacity | 1500W |
2 | Rated heating capacity | 300/500W (optional) |
3 | Rated input current | 2.6A |
4 | Rated input power | 580W |
5 | Rated input voltage | 220±15%VAC~50Hz |
7 | Noise | 65dB |
8 | IP Grade | IP55 |
9 | Weight | 24kg |
10 | Working environmental temperature | -40°C ~ 55°C |
11 | Storage working temperature | -40°C ~ 70°C |
12 | Working humidity | ≤95% |
III | Other accessories | |
1 | AC distribution box | AC input: 63A MCB *1 AC output 10A socket *5 Including SPD, 40KA Height: 3U |
2 | LED light | DC48V |
3 | LED light switch | Control light on or off |
4 | Ventilation fan | Two AC220V fans |
4. Cabinet Feature
(1) Embedded structure design make the door strong and protect from illigal open.
(2) Sandwich structure panel, double layer galvanized steel plate with heat insulation.
(3) Air conditioner cooling can provid good conditions for internal cooling equipment
(4) 19 inch standard rack.
(5) Protection grade IP55, effectively prevent rainwater leakage.
(6) The door lock adopts the special mechanical lock for outdoor cabinet, and the three-point locking structure provides reliable safety protection for the cabinet.
5. Cabinet Advantage
· Double wall with heat insulation can protect inside equipment against sudden heat shock
· Multi-stage cleaning and pre-treatment prior to the application of a 120micron powder coating
· The cabinet structure have earthquake resistance function
· Outdoor cabinet is compact and durable, space layout is reasonable, greatly reducing the construction cost
· Waterproof, fire proof, anti-corrosion, anti sand and anti ultraviolet, ensure cabinet can work longer in a harsh outdoor environment
· Inside screws, improve the safety
6. Cabinet Picture Display
7. Cabinet Power Distribution unit diagram
8. Other outdoor telecom cabinet
Tag:
telecom equipment cabinet,outdoor telecom enclosure,outdoor communication cabinets